G1184

INQUIRY READY

G1184-2200WNA

Gospower / AC/DC Platinum / G1184

G1184-2200WNA is a specialized choice for AI Training Nodes, Cloud Storage, and Distributed Compute Systems; 2200W capacity underpins an installation-ready choice for mission-critical equipment.

Output Power (W):
2200
Length (mm):
195
Width (mm):
73.5
Height (mm):
40

Need compatibility confirmation? Send us your model, label photo, power rating, and connector requirements.

PRODUCT OVERVIEW

Built for reliable, continuous power delivery.

The G1184-2200WNA is suitable for infrastructure platforms that require maximum 12V power density, compact CRPS integration, and reliable operation under sustained high-load conditions. Its 2200W output makes it a strong fit for AI training nodes, cloud storage systems, distributed compute clusters, HPC edge systems, and hyperscale rack environments where uptime, power stability, and thermal control are essential. Allow practical headroom for startup demand and transient loads, while keeping intake and exhaust paths clear throughout continuous operation. Before integration, confirm the connector mapping, chassis clearance, and supported input conditions against the target power shelf.

Before integrating the G1184-2200WNA, confirm the mating connector or backplane, input source, output-rail requirements, hot-swap sequence, airflow direction, monitoring interface, redundancy behavior, and service clearance against the target platform.

CORE ADVANTAGES

2200W CRPS Power Supply for AI Training Nodes, Cloud Storage, and Distributed Compute Systems

2200W Power for High-Density AI Infrastructure The G1184-2200WNA is designed for AI training infrastructure, cloud storage platforms, distributed compute systems, and dense rack environments that require very high power density in a compact CRPS power module.

01

2200W Power for High-Density AI Infrastructure The G1184-2200WNA is designed for AI training infrastructure, cloud storage platforms, distributed compute systems, and dense rack environments that require very high power density in a compact CRPS power module.

02

CRPS 1U Format for Dense Rack Deployment With a 195 × 73.5 × 40 mm mechanical size, this model supports high-density rack systems where power capacity, airflow planning, service access, and compact installation are critical.

03

Wide AC and DC Input Compatibility It supports 90–264Vac AC input and 180–300Vdc DC input, allowing deployment across global data centers, cloud facilities, telecom rooms, edge sites, and high-performance infrastructure environments.

04

High-Current 12V Output for Heavy Compute Loads The unit provides a 12V main output at 183A and a 12V standby output at 2.1A, supporting GPUs, CPUs, memory arrays, storage controllers, system fans, and control logic.

05

Digital Power Control with PMBus Monitoring With digital power control and PMBus 1.2 support, the G1184-2200WNA enables compatible platforms to monitor operating status, telemetry, power conditions, and fault information.

06

Built for Efficient Mission-Critical Operation High efficiency, active PFC, adaptive fan-speed control, and reverse-airflow availability help this model support stable long-term operation in demanding AI, cloud, storage, and distributed compute environments.

MODEL SELECTION

Compare Gospower power options.

Review nearby Gospower models and select the power level, output architecture, efficiency grade, and form factor that best match the target system.

Model Power Output Current Efficiency Form Factor Recommended Use
G1184-2000WNA 2000w 12V Platinum CRPS AI training servers and high-speed storage nodes
G1184-2200WNA 2200w 12V Platinum CRPS Dense GPU clusters and hyperscale compute racks

DEPLOYMENT SCENARIOS

Where G1184-2200WNA fits best.

The G1184-2200WNA is suitable for infrastructure platforms that require maximum 12V power density, compact CRPS integration, and reliable operation under sustained high-load conditions. Its 2200W output makes it a strong fit for AI training nodes, cloud storage systems, distributed compute clusters, HPC edge systems, and hyperscale rack environments where uptime, power stability, and thermal control are essential.

Scenario System Requirement Why G1184-2200WNA Fits
AI Training Nodes Strong power support for GPUs, CPUs, memory, and cooling systems 2200W output provides high operating headroom for multi-GPU training workloads
Cloud Storage Platforms Stable output for NVMe storage, controllers, backplanes, and fans 183A 12V output supports storage-heavy systems with high current demand
Distributed Compute Systems Reliable power for scalable compute nodes across multiple deployment sites Wide input range supports flexible infrastructure and global power environments
HPC Edge Systems Compact power for remote high-performance compute and inference workloads CRPS form factor fits space-limited edge and cabinet-based deployments
Dense Compute Racks High power density for rack-mounted servers and accelerator platforms 2200W capacity supports demanding compute loads within a compact PSU footprint
Hyperscale Data Centers Continuous power for large-scale cloud and data infrastructure PMBus visibility and adaptive cooling support monitoring and service planning

POWER DESIGN

Reliability notes for continuous operation.

The G1184-2200WNA is built for high-performance infrastructure where power density, thermal stability, and monitoring visibility directly affect system uptime. Its 2200W output and 183A 12V main rail provide strong current delivery for AI acceleration, cloud storage, distributed compute, and dense rack platforms.

  • 2200W output capacity supports AI training nodes, cloud storage systems, distributed compute platforms, HPC edge systems, and dense data center racks.
  • 12V main output at 183A provides high-current power for GPUs, CPUs, memory, NVMe storage, network modules, fans, and control boards.
  • 12V standby output at 2.1A supports management controllers, standby operation, monitoring circuits, and auxiliary system logic.
  • Active PFC helps improve input power quality and supports efficient conversion across different AC operating conditions.
  • Wide AC/DC input compatibility allows deployment in data centers, cloud facilities, telecom rooms, edge cabinets, and global infrastructure sites.
  • PMBus 1.2 communication provides visibility into voltage, current, operating status, telemetry, and fault information in supported systems.
  • Adaptive fan-speed control adjusts cooling performance based on thermal demand and system load behavior.
  • Reverse-airflow availability supports front-to-back or back-to-front cooling layouts in varied rack and chassis designs.

INSTALLATION

Installation and operating guidance.

Confirm electrical compatibility, thermal clearance, mechanical fit, redundancy requirements, and system load before integration.

Installation / Operation Item Guidance
Load Planning Review total demand from GPUs, CPUs, memory arrays, storage controllers, network modules, fans, and management circuits before deployment
Chassis Fitment Confirm the 195 × 73.5 × 40 mm CRPS size before mechanical integration
Input Connection Use within the supported 90–264Vac or 180–300Vdc input range
GPU Load Check Leave sufficient margin for accelerator startup behavior, AI training bursts, and peak compute demand
Standby Power Check Verify that the target platform standby requirement matches the 2.1A 12V standby output
Airflow Direction Match standard or reverse airflow with the chassis cooling layout
Monitoring Setup Use PMBus 1.2 where supported for telemetry, fault alerts, and maintenance visibility
Service Inspection Inspect fan condition, connector seating, dust buildup, and airflow path during regular service intervals

FAQ

Frequently asked questions about G1184-2200WNA.

Key answers for specification matching, installation planning, and system integration.

What type of power supply is the G1184-2200WNA?

The G1184-2200WNA is a 2200W CRPS power supply designed for AI training nodes, cloud storage platforms, distributed compute systems, HPC edge systems, and dense rack infrastructure.

What is the size of this model?

This model uses a CRPS 1U form factor with a size of 195 × 73.5 × 40 mm, making it suitable for compact high-density rack integration.

What input voltage range does it support?

The G1184-2200WNA supports 90–264Vac AC input and 180–300Vdc DC input for flexible deployment across different infrastructure power environments.

What output does the G1184-2200WNA provide?

It provides a 12V main output at 183A and a 12V standby output at 2.1A for system operation, standby functions, and management control circuits.

Is this model suitable for AI training infrastructure?

Yes. Its 2200W output and high-current 12V rail make it suitable for AI training nodes, multi-GPU servers, accelerator platforms, and dense compute racks.

Does the G1184-2200WNA support PMBus monitoring?

Yes. The unit supports PMBus 1.2, allowing compatible systems to monitor operating status, telemetry, power conditions, and fault information.

Can this model support reverse airflow?

Yes. A reverse-airflow option is available for systems that require front-to-back or back-to-front cooling layouts.

What infrastructure is this model best suited for?

The G1184-2200WNA is best suited for AI training infrastructure, cloud storage systems, distributed compute platforms, HPC edge systems, and high-density data center racks.