NHP series

INQUIRY READY

GW-NHP500SW-12

Greatwall / Industrial Power Supply / NHP series

GW-NHP500SW-12 applies 500.4W capacity and a stable 12Vdc rail across Energy Saving, Edge Computing, Security Systems, Industrial Displays, and Network Appliances; the result is dependable performance across distributed operating sites.

Power Supply Type
AC/DC enclosed switching power supply
Rated Output Voltage
12Vdc
Rated Output Current
41.7A
Rated Output Power
500.4W

Need compatibility confirmation? Send us your model, label photo, power rating, and connector requirements.

PRODUCT OVERVIEW

Built for reliable, continuous power delivery.

The GW-NHP500SW-12 is designed for equipment requiring a stable 12V rail with substantial current capacity. Its compact enclosure, wide input range, fanless cooling, and optional monitoring functions make it suitable for continuously operating computing, security, networking, and industrial platforms. For this 500.4W capacity, 12Vdc output, allow practical headroom for startup demand and transient loads, while keeping intake and exhaust paths clear throughout continuous operation. Before integration, confirm the connector mapping, chassis clearance, and supported input conditions against the target power shelf. For long-term service, document fan inspection, connector seating, event-log review, and replacement procedures as part of the maintenance plan. Commissioning should verify grounding, input protection, output stability, and the response of any redundant or hot-swap control logic. A documented acceptance test helps preserve consistent behavior when modules, backplanes, or surrounding hardware are serviced.

Plan the GW-NHP500SW-12 output wiring around the actual current demand: keep conductors short, use low-resistance terminations, separate power paths from sensitive signal wiring, and preserve access for retightening and inspection. Arrange the enclosure so heat from neighboring components cannot collect around the supply or its connection points.

Qualify the GW-NHP500SW-12 at several load levels, measuring voltage at both the supply terminals and the equipment input rather than relying only on no-load readings. Record cable drop, connector temperature, and enclosure temperature as baseline values. Later maintenance checks can compare against this record to identify loose joints, rising contact resistance, or deteriorating heat dissipation before they interrupt service.

CORE ADVANTAGES

500.4W 12V 41.7A Slim AC/DC Power Supply for Edge Computing, Security Systems, Network Appliances, and Industrial Electronics

The GW-NHP500SW-12 delivers a regulated 12V output at up to 41.7A, providing 500.4W of rated output power. It is suitable for edge-computing platforms, network appliances, surveillance equipment, embedded computers, display systems, and other high-load electronics requiring a stable 12V DC rail.

01

High-Power 12V DC Output

The GW-NHP500SW-12 delivers a regulated 12V output at up to 41.7A, providing 500.4W of rated output power. It is suitable for edge-computing platforms, network appliances, surveillance equipment, embedded computers, display systems, and other high-load electronics requiring a stable 12V DC rail.

02

Slim 31 mm Enclosed Construction

With dimensions of 232 × 80 × 31 mm, the power supply combines more than 500W of output capability with a compact mechanical profile. Its elongated metal enclosure supports installation in narrow equipment bays, communication chassis, industrial cabinets, and space-constrained electronic systems.

03

Universal AC and High-Voltage DC Input

The unit supports 90–264Vac input and 127–370Vdc input, allowing operation across different regional AC grids and selected high-voltage DC distribution environments. Built-in active PFC improves input current characteristics and supports stable front-end power conversion.

04

High Efficiency up to 94%

Conversion efficiency of up to 94% helps reduce system energy losses and internal heat generation. This supports more efficient continuous operation in network equipment, security platforms, embedded systems, and industrial electronics.

05

Fanless Semi-Potted Design

The GW-NHP500SW-12 uses free-air convection cooling without an integrated fan. Its semi-potted internal construction improves resistance to vibration, humidity, dust, and environmental stress while reducing acoustic noise, moving-part wear, and maintenance requirements.

06

Integrated Protection and Optional System Functions

The power supply includes output short-circuit, overcurrent, overvoltage, and overtemperature protection. It also provides an output LED indicator and adjustable output voltage, while optional DC OK signaling and redundant operation can support status monitoring and higher-availability equipment designs.

MODEL SELECTION

Compare Greatwall industrial power options.

Review nearby Greatwall models and select the output voltage, power level, and integration profile that best match the target system.

Model Best-Fit Application
GW-NHP500SW-4.2 Battery formation equipment, cell-testing platforms, laboratory systems, and high-current 4.2V loads
GW-NHP500SW-5 Embedded computing, storage backplanes, LED display electronics, and high-current 5V systems
GW-NHP500SW-12 Edge computers, network appliances, security equipment, industrial displays, and high-power 12V electronics
GW-NHP500SW-15 Automated test systems, machine-vision equipment, broadcast electronics, and specialized 15V loads
GW-NHP500SW-24 Factory automation, robotics, machine vision, control cabinets, and standard 24V industrial loads
GW-NHP500SW-36 Mobile robots, industrial actuators, motion-control systems, and specialized 36V equipment
GW-NHP500SW-48 Telecom infrastructure, PoE systems, network equipment, and distributed 48V platforms
GW-NHP500SW-55 High-power PoE equipment, telecom radio systems, edge communications, and specialized 55V loads

DEPLOYMENT SCENARIOS

Where GW-NHP500SW-12 fits best.

The GW-NHP500SW-12 is designed for equipment requiring a stable 12V rail with substantial current capacity. Its compact enclosure, wide input range, fanless cooling, and optional monitoring functions make it suitable for continuously operating computing, security, networking, and industrial platforms.

Deployment Scenario Application Value
Edge and Embedded Computing Supplies 12V power to industrial PCs, edge servers, embedded motherboards, GPU-assisted controllers, and interface modules
Security and Surveillance Systems Supports NVRs, video-processing units, access-control equipment, alarm platforms, and integrated surveillance systems
Network Appliances Powers routers, firewalls, gateways, communication controllers, and other high-performance network equipment
Industrial Display Systems Provides regulated power for display controllers, digital-signage processors, HMI platforms, and large-format display electronics

POWER DESIGN

Reliability notes for continuous operation.

The GW-NHP500SW-12 combines a 500.4W 12V output with active PFC, natural convection cooling, and semi-potted construction. It is optimized for compact systems requiring reliable high-current power delivery without an integrated cooling fan.

  • Supports 90–264Vac universal input and 127–370Vdc input.
  • Delivers 12V at up to 41.7A with 500.4W rated output power.
  • Built-in active PFC improves input current quality.
  • Provides efficiency of up to 94%.
  • Uses fanless free-air convection cooling.
  • Semi-potted construction improves resistance to environmental stress.
  • Includes short-circuit, overcurrent, overvoltage, and overtemperature protection.
  • Supports installations up to 5,000 meters, with optional DC OK and redundant functions available.

INSTALLATION

Installation and operating guidance.

Confirm electrical compatibility, thermal clearance, mechanical fit, and system load before integration.

Item Guidance
Mounting Orientation Secure the unit firmly using the designated chassis mounting points
Ventilation Clearance Maintain sufficient open space around the perforated enclosure for natural airflow
Input Wiring Confirm whether the installation uses AC or high-voltage DC input before connection
Output Cable Sizing Use short, low-resistance conductors rated to safely carry up to 41.7A
Terminal Connection Tighten all screw terminals securely to minimize resistance and localized heating
Grounding Connect protective earth correctly before applying input power
Output Adjustment Verify the adjusted voltage with a calibrated meter before connecting sensitive equipment
Voltage Drop Control Account for cable, terminal, and connector losses in high-current 12V installations
Load Distribution Use suitable busbars or multiple conductors when distributing current to several loads
Temperature Management Apply appropriate load derating or additional enclosure airflow near the upper temperature limit

FAQ

Frequently asked questions about GW-NHP500SW-12.

Key answers for specification matching, installation planning, and system integration.

What type of power supply is the GW-NHP500SW-12?

It is a slim enclosed AC/DC switching power supply with a regulated 12V output, built-in active PFC, screw-terminal connections, and fanless convection cooling.

What are the dimensions of the GW-NHP500SW-12?

The unit measures 232 × 80 × 31 mm, making it suitable for narrow equipment compartments and compact electronic systems.

What input voltage range does it support?

It supports 90–264Vac input and 127–370Vdc input.

What output power and current does it provide?

It delivers 12V at up to 41.7A, providing 500.4W of rated output power.

Is it suitable for edge-computing and embedded systems?

Yes. Its high-current 12V output is suitable for compatible industrial PCs, edge servers, embedded motherboards, interface modules, and computing controllers.

Can it power security and surveillance equipment?

Yes. It can support compatible NVRs, video-processing platforms, access-control systems, alarm equipment, and other security electronics, provided the total load remains within specification.

Does the power supply require an integrated cooling fan?

No. It uses free-air convection cooling, so adequate ventilation clearance must be maintained around the enclosure.

What protection and monitoring functions are available?

The unit includes short-circuit, overcurrent, overvoltage, and overtemperature protection. Optional DC OK signaling and redundant operating functions are also available.