G1179

INQUIRY READY

G1179-0550WNA

Gospower / 1+1 2U PDB / G1179

G1179-0550WNA focuses on Cloud Servers, Data Centers, and Network Infrastructure, where a design centered on 550W capacity supports stable service across demanding field environments.

Output Power (W):
550
Length (mm):
265
Width (mm):
77
Height (mm):
84

Need compatibility confirmation? Send us your model, label photo, power rating, and connector requirements.

PRODUCT OVERVIEW

Built for reliable, continuous power delivery.

The G1179-0550WNA is suitable for compact 2U systems that require stronger power distribution than lower-wattage G1179 models while still maintaining a space-efficient internal structure. Its 550W output capacity and multi-rail design make it a practical fit for cloud servers, data center appliances, storage-cache systems, network infrastructure, and edge service platforms where stable rail distribution, redundancy support, and reliable operation are important.

Before integrating the G1179-0550WNA, confirm the mating connector or backplane, input source, output-rail requirements, hot-swap sequence, airflow direction, monitoring interface, redundancy behavior, and service clearance against the target platform.

CORE ADVANTAGES

550W 2U Power Distribution Board for Cloud Servers, Data Centers, and Network Infrastructure

550W Power Distribution for Compact Cloud Infrastructure The G1179-0550WNA is designed for cloud servers, data center equipment, network infrastructure, storage systems, and compact service platforms that require stable internal power distribution in a 2U architecture.

01

550W Power Distribution for Compact Cloud Infrastructure The G1179-0550WNA is designed for cloud servers, data center equipment, network infrastructure, storage systems, and compact service platforms that require stable internal power distribution in a 2U architecture.

02

2U Power Distribution Board Structure With a 265 × 77 × 84 mm mechanical size, this model supports compact 2U chassis layouts where multi-rail power routing, organized cable integration, and reliable system-level distribution are important.

03

1+1 Redundant Power Architecture The board supports a 1+1 redundant configuration, helping improve power availability in systems where continuous operation, backup power paths, service access, and uptime protection are required.

04

Multiple Output Rails for System Integration The G1179-0550WNA provides +12V, +5V, +3.3V, -12V, and +5V standby outputs, supporting server boards, storage logic, network modules, cooling systems, standby circuits, and auxiliary electronic components.

05

Designed for Cloud, Data Center, and Network Platforms This power distribution board is suitable for cloud server nodes, compact data center appliances, storage-cache systems, network service platforms, aggregation equipment, and embedded infrastructure requiring organized internal power delivery.

06

Built for Reliable Internal Power Delivery With redundant architecture, multi-rail output support, compact 2U mechanical integration, digital monitoring support, and safety/EMC compliance options, the G1179-0550WNA helps simplify internal power distribution for compact but higher-load infrastructure systems.

MODEL SELECTION

Compare Gospower power options.

Review nearby Gospower models and select the power level, output architecture, efficiency grade, and form factor that best match the target system.

Model Power Use Role Input Form Factor Best-Fit Application
G1179-0150WNA 150w Standby and control-board power distribution AC/DC 1+1 2U PDB Compact control servers, monitoring units, and low-power storage logic
G1179-0250WNA 250w Entry-level redundant PDB for edge service hardware AC/DC 1+1 2U PDB Branch gateways, access appliances, and small edge compute boxes
G1179-0350WNA 350w Multi-rail distribution for storage and service nodes AC/DC 1+1 2U PDB NAS controllers, backup systems, lightweight VM nodes, and edge data devices
G1179-0460WNA 460w Balanced power board for network and I/O-heavy systems AC/DC 1+1 2U PDB Routing platforms, SD-WAN appliances, firewall systems, and service gateways
G1179-0550WNA 550w Higher-margin PDB for compact compute expansion AC/DC 1+1 2U PDB Micro server clusters, storage-cache platforms, and compact hosting appliances
G1179-0800WNA 800w Integrated compute-storage distribution platform AC/DC 1+1 2U PDB POP edge nodes, CDN cache systems, aggregation appliances, and edge data platforms
G1179-1300WNA 1300w High-capacity 2U PDB for dense service infrastructure AC/DC 1+1 2U PDB AI-assisted edge nodes, high-density compute appliances, and hybrid workload systems
G1179-1600WNA Peak Peak-load 2U PDB for scalable compact infrastructure AC/DC 1+1 2U PDB

DEPLOYMENT SCENARIOS

Where G1179-0550WNA fits best.

The G1179-0550WNA is suitable for compact 2U systems that require stronger power distribution than lower-wattage G1179 models while still maintaining a space-efficient internal structure. Its 550W output capacity and multi-rail design make it a practical fit for cloud servers, data center appliances, storage-cache systems, network infrastructure, and edge service platforms where stable rail distribution, redundancy support, and reliable operation are important.

Scenario System Requirement Why G1179-0550WNA Fits
Cloud Server Nodes Internal power routing for compute boards, memory, storage access, fans, and management circuits 550W capacity provides stronger headroom for compact cloud server hardware
Data Center Appliances Stable rail support for service boards, storage logic, network modules, and cooling devices Multi-rail output supports mixed infrastructure workloads
Storage-Cache Systems Power distribution for storage controllers, cache modules, backplane logic, and drive-related electronics +12V, +5V, and +3.3V rails support storage and cache platform requirements
Network Infrastructure Reliable power support for routing boards, switching logic, interface cards, and monitoring circuits 2U PDB layout supports dense network equipment integration
Edge Service Platforms Board-level power delivery for local compute, I/O modules, storage, and standby logic Compact structure supports distributed deployment environments
Redundant Compact Systems Backup power path support for equipment requiring improved service continuity 1+1 redundant architecture helps strengthen system availability

POWER DESIGN

Reliability notes for continuous operation.

The G1179-0550WNA is built for compact cloud, data center, storage, networking, and edge infrastructure where internal power distribution, multiple voltage rails, and redundant architecture are critical to system reliability. Its 2U structure helps system designers manage several output rails inside constrained chassis while supporting 1+1 redundancy for improved uptime and service continuity.

  • 550W power distribution capacity supports cloud server nodes, data center appliances, storage-cache systems, network infrastructure, edge service platforms, and redundant compact systems.
  • 1+1 redundant design helps improve power availability by supporting backup power path architecture in compatible system designs.
  • +12V output at 45A supports main system loads, server boards, network modules, storage-related components, cooling devices, and board-level power routing.
  • +5V output at 25A supports logic circuits, storage electronics, interface boards, auxiliary modules, and control-related components.
  • +3.3V output at 25A supports low-voltage digital circuits, embedded logic, communication modules, and onboard electronic devices.
  • -12V output at 0.5A supports legacy or auxiliary signal requirements in compatible system designs.
  • +5V standby output at 3A supports standby logic, management controllers, monitoring circuits, and system wake functions.
  • 265 × 77 × 84 mm mechanical structure supports compact 2U chassis integration and organized internal installation.
  • Broad AC/DC input compatibility supports flexible deployment across different power environments.
  • Digital control and PMBus 1.2 support help compatible systems monitor power behavior, operating status, and diagnostic information.

INSTALLATION

Installation and operating guidance.

Confirm electrical compatibility, thermal clearance, mechanical fit, redundancy requirements, and system load before integration.

Installation / Operation Item Guidance
System Role Check Confirm that the target system requires a 2U power distribution board rather than a standalone CRPS power supply module
Redundancy Planning Verify that the chassis and upstream power modules support the intended 1+1 redundant configuration
Chassis Fitment Confirm the 265 × 77 × 84 mm mechanical size before installation
Output Rail Matching Check +12V, +5V, +3.3V, -12V, and +5V standby requirements against the target system load
Load Budget Review Calculate total power demand from server boards, storage logic, network modules, fans, standby circuits, and control components
Connector Compatibility Confirm connector layout, cable harness routing, pin definition, and mating interfaces before integration
Thermal Layout Ensure proper airflow around the board, cable harnesses, and nearby heat-generating components
System Validation Test startup behavior, standby function, redundancy response, rail stability, thermal behavior, and load response before deployment

FAQ

Frequently asked questions about G1179-0550WNA.

Key answers for specification matching, installation planning, and system integration.

What type of product is the G1179-0550WNA?

The G1179-0550WNA is a 550W 2U power distribution board designed for cloud servers, data center appliances, storage-cache systems, network infrastructure, and compact edge service platforms.

What is the size of this model?

This model uses a compact 2U structure with a size of 265 × 77 × 84 mm, making it suitable for space-constrained internal system layouts.

What systems is this model suitable for?

It is suitable for cloud server nodes, compact data center equipment, storage-cache systems, network service appliances, aggregation platforms, embedded infrastructure, and edge service hardware.

Does the G1179-0550WNA support redundant power architecture?

Yes. The board supports a 1+1 redundant configuration, helping improve power availability in compatible system designs.

What output rails does this board provide?

The G1179-0550WNA provides multiple output rails, including +12V at 45A, +5V at 25A, +3.3V at 25A, -12V at 0.5A, and +5V standby at 3A.

Why is this model suitable for cloud servers and data center appliances?

Its 550W capacity and multi-rail output design can support compute boards, storage logic, network modules, management circuits, standby functions, and cooling systems in compact 2U infrastructure equipment.

What makes this model different from the G1179-0460WNA?

Compared with the G1179-0460WNA, the G1179-0550WNA provides higher overall power distribution capacity and stronger +12V rail support, making it better suited for cloud server nodes, storage-cache systems, data center appliances, and network infrastructure with heavier internal load demand.

What should be checked before integrating this board?

Confirm the mechanical fit, connector interface, output rail requirements, total load budget, redundancy design, cable harness layout, airflow path, thermal margin, and system-level compatibility before integration.