G1358

INQUIRY READY

G1358-2000WNA

Gospower / AC/DC Titanium / G1358

G1358-2000WNA serves High-Density Compute Servers, Large-Scale Storage Systems, Network & Core Infrastructure, and Data Centers & Cloud Environments through 2000W capacity. This configuration delivers controlled delivery for equipment expected to run for long periods.

Output Power (W):
2000
Length (mm):
185
Width (mm):
73.5
Height (mm):
40

Need compatibility confirmation? Send us your model, label photo, power rating, and connector requirements.

PRODUCT OVERVIEW

Built for reliable, continuous power delivery.

The G1358-2000WNA is suitable for high-load infrastructure that requires maximum 12V power capacity in a compact CRPS footprint. Its 2000W output makes it a strong fit for dense compute stacks, high-performance servers, accelerator platforms, storage-heavy systems, network service appliances, and mission-critical data center infrastructure where power headroom, thermal control, and monitoring visibility are essential. Qualification should include airflow direction, thermal margin, cable routing, and access for routine module replacement. Backplane pinout, control signaling, and mechanical retention should be checked together before the unit is approved for production use.

Before integrating the G1358-2000WNA, confirm the mating connector or backplane, input source, output-rail requirements, hot-swap sequence, airflow direction, monitoring interface, redundancy behavior, and service clearance against the target platform.

CORE ADVANTAGES

2000W CRPS Power Supply Designed for Robust Server and Networking Applications

2000W Power for High-Load Infrastructure The G1358-2000WNA is designed for demanding server, storage, networking, and dense compute environments that require powerful 2000W output in a compact CRPS power module.

01

2000W Power for High-Load Infrastructure The G1358-2000WNA is designed for demanding server, storage, networking, and dense compute environments that require powerful 2000W output in a compact CRPS power module.

02

Compact 1U CRPS Mechanical Design With a 185 × 73.5 × 40 mm form factor, this model supports high-density server chassis, modular compute systems, network appliances, and space-constrained rack infrastructure.

03

Wide AC and DC Input Compatibility It supports 90–264Vac AC input and 180–300Vdc DC input, allowing flexible deployment across data centers, server rooms, network cabinets, edge sites, and global infrastructure environments.

04

High-Current 12V Output Delivery The unit provides a regulated 12V main output at 166.66A together with a 12V standby output at 2.1A, supporting processors, accelerator cards, storage controllers, network boards, fans, and management circuits.

05

PMBus 1.2 Digital Monitoring With advanced digital control and PMBus 1.2 support, the G1358-2000WNA enables compatible systems to monitor power status, telemetry, fault information, voltage behavior, and remote operating conditions.

06

Built for Mission-Critical Performance Titanium-level efficiency, active PFC, intelligent fan control, reverse airflow support, and major safety and EMC compliance options help this model support stable operation in critical server and networking environments.

MODEL SELECTION

Compare Gospower power options.

Review nearby Gospower models and select the power level, output architecture, efficiency grade, and form factor that best match the target system.

Model Power Output Current Efficiency Form Factor Recommended Use
G1358-0800WNA 800w 12V Titantium CRPS Edge service nodes and compact firewall systems
G1358-1300WNA 1300w 12V Titantium CRPS Multi-service compute platforms and network appliances
G1358-1600WNA 1600w 12V Titantium CRPS CPU/GPU hybrid servers and accelerated workloads
G1358-2000WNA 2000w 12V Titantium CRPS Dense compute stacks and high-load infrastructure

DEPLOYMENT SCENARIOS

Where G1358-2000WNA fits best.

The G1358-2000WNA is suitable for high-load infrastructure that requires maximum 12V power capacity in a compact CRPS footprint. Its 2000W output makes it a strong fit for dense compute stacks, high-performance servers, accelerator platforms, storage-heavy systems, network service appliances, and mission-critical data center infrastructure where power headroom, thermal control, and monitoring visibility are essential.

Scenario System Requirement Why G1358-2000WNA Fits
Dense Compute Stacks Strong power for multi-node compute, memory expansion, fans, and control boards 2000W output provides high power headroom in compact rack systems
High-Performance Servers Stable 12V delivery for CPUs, memory, storage, I/O cards, and cooling systems 12V output at 166.66A supports demanding server configurations
Accelerator Platforms Reliable output for GPU cards, AI acceleration, analytics, and high-throughput workloads High-current 12V rail supports heavy accelerator-assisted operation
Storage-Heavy Systems Continuous power for controllers, backplanes, SSD arrays, drive bays, and fans 2000W capacity supports large storage expansion and sustained access
Network Service Appliances Power support for routing, firewall, SD-WAN, security, and traffic processing modules Compact CRPS structure fits dense network appliance chassis
Critical Data Center Infrastructure Stable operation with power visibility and service planning PMBus 1.2 support helps improve diagnostics, monitoring, and maintenance response

POWER DESIGN

Reliability notes for continuous operation.

The G1358-2000WNA is built for robust server, storage, networking, and accelerated infrastructure where high-current 12V delivery, compact integration, and efficient thermal management are critical. Its 2000W rating provides substantial operating margin for dense compute stacks, high-load server nodes, storage expansion, and mission-critical network systems.

  • 2000W output capacity supports dense compute stacks, high-performance servers, accelerator platforms, storage-heavy systems, and network service appliances.
  • 12V main output at 166.66A supports processors, GPU cards, memory systems, storage controllers, backplanes, network cards, and cooling fans.
  • 12V standby output at 2.1A supports management logic, standby operation, monitoring circuits, and auxiliary system control.
  • Titanium-level efficiency helps reduce energy loss and thermal load during sustained high-power operation.
  • Active PFC helps improve input power quality and supports stable operation across different AC power conditions.
  • Wide AC/DC input compatibility allows deployment across data centers, server rooms, network cabinets, edge sites, and global infrastructure environments.
  • PMBus 1.2 communication provides visibility into power status, telemetry, fault information, voltage behavior, and operating conditions in supported systems.
  • Intelligent fan control and reverse airflow support help match different chassis cooling paths in dense rack environments.

INSTALLATION

Installation and operating guidance.

Confirm electrical compatibility, thermal clearance, mechanical fit, redundancy requirements, and system load before integration.

Installation / Operation Item Guidance
Load Planning Review CPU demand, GPU or accelerator load, storage expansion, network module power, fan consumption, and standby requirements before deployment
Chassis Fitment Confirm the 185 × 73.5 × 40 mm CRPS size before mechanical integration
Input Connection Use within the supported 90–264Vac or 180–300Vdc input range
Output Compatibility Verify that the target system is designed for 12V main power input
Standby Power Check Confirm that the platform standby requirement matches the 2.1A 12V standby output
Thermal Margin Leave sufficient airflow clearance for 2000W high-current operation in dense chassis
Airflow Direction Match standard or reverse airflow with the chassis cooling path
Monitoring Setup Use PMBus 1.2 where supported for telemetry, diagnostics, fault alerts, and maintenance visibility

FAQ

Frequently asked questions about G1358-2000WNA.

Key answers for specification matching, installation planning, and system integration.

What type of power supply is the G1358-2000WNA?

The G1358-2000WNA is a 2000W CRPS power supply designed for robust server systems, dense compute stacks, networking equipment, storage-heavy platforms, and critical infrastructure.

What is the size of this model?

This model uses a compact 1U CRPS form factor with a size of 185 × 73.5 × 40 mm, making it suitable for dense rack configurations and space-constrained chassis designs.

What input voltage range does it support?

The G1358-2000WNA supports 90–264Vac AC input and 180–300Vdc DC input for flexible deployment across different infrastructure power environments.

Does the G1358-2000WNA support PMBus monitoring?

Yes. The unit supports PMBus 1.2, allowing compatible systems to monitor power status, telemetry, fault information, voltage behavior, and operating conditions.

Why is this model suitable for dense compute stacks?

Its 2000W output and 12V main rail rated at 166.66A provide strong power capacity for multi-node compute, processors, memory, I/O cards, fans, and management logic.

How does this PSU support accelerator platforms?

The high-current 12V output helps support GPU cards, AI acceleration modules, analytics systems, and other high-throughput workloads that require strong power headroom.

What makes this model different from the G1358-1600WNA?

Compared with the G1358-1600WNA, this 2000W model provides a larger 12V current budget, making it better suited for heavier compute stacks, storage expansion, and maximum-load infrastructure.

What should be checked before integrating this PSU?

Confirm the 12V input requirement, 12V standby demand, connector compatibility, chassis clearance, airflow direction, reverse airflow requirement, thermal margin, and PMBus support before deployment.