CRPS2000N3

Greatwall / Server Power Supply / CRPS

CRPS2000N3 brings together 2000W capacity and a stable +12V / 65.6A rail for Data Center Servers, Cloud Computing Nodes, Storage Platforms, and AI/Hpc Systems, with an emphasis on controlled delivery for equipment expected to run for long periods.

Model
CRPS2000N3
Input Voltage
90VAC–264VAC or 180VDC–320VDC
Standby Output
+12VSB / 3A
Output Power
2000W

Need compatibility confirmation? Send us your model, label photo, power rating, and connector requirements.

PRODUCT OVERVIEW

Built for reliable, continuous power delivery.

The CRPS2000N3 is designed for server systems that require higher output capacity while still using a compact CRPS mechanical structure. It is suitable for data center servers, cloud computing nodes, storage platforms, high-performance computing systems, and enterprise infrastructure where strong 12V delivery, efficiency, and stable thermal behavior are important. For this 2000W capacity, +12V / 65.6A, +12V / 148A, +12V / 164A output, allow practical headroom for startup demand and transient loads, while keeping intake and exhaust paths clear throughout continuous operation.

Plan the CRPS2000N3 output wiring around the actual current demand: keep conductors short, use low-resistance terminations, separate power paths from sensitive signal wiring, and preserve access for retightening and inspection. Arrange the enclosure so heat from neighboring components cannot collect around the supply or its connection points.

Qualify the CRPS2000N3 at several load levels, measuring voltage at both the supply terminals and the equipment input rather than relying only on no-load readings. Record cable drop, connector temperature, and enclosure temperature as baseline values. Later maintenance checks can compare against this record to identify loose joints, rising contact resistance, or deteriorating heat dissipation before they interrupt service.

CORE ADVANTAGES

2000W CRPS Power Supply for High-Density Server and Advanced Infrastructure Platforms

The CRPS2000N3 delivers 2000W output for high-density servers, cloud computing nodes, storage systems, and advanced infrastructure platforms that require stronger 12V power capacity.

01

2000W High-Capacity CRPS Power Output

The CRPS2000N3 delivers 2000W output for high-density servers, cloud computing nodes, storage systems, and advanced infrastructure platforms that require stronger 12V power capacity.

02

Compact 185 × 73.5 × 40 mm CRPS Structure

Built in a standard 185 × 73.5 × 40 mm CRPS form factor, this model provides high power density while fitting compact server chassis and space-limited rack systems.

03

Wide AC and DC Input Compatibility

It supports 90VAC–264VAC AC input and 180VDC–320VDC DC input , making it suitable for different rack power environments, data center rooms, and infrastructure power designs.

04

Multiple 12V Main Output Options

The unit provides +12V / 65.6A , +12V / 148A , and +12V / 164A output configurations, together with +12VSB / 3A standby output for system control and standby operation.

05

Platinum Efficiency for 24/7 Operation

With Platinum efficiency , the CRPS2000N3 helps reduce power loss, improve conversion performance, and support better thermal control in continuous server workloads.

06

Reliable Certification Coverage for Global Deployment

With certifications including CE, CQC, IRAM, TUV, UKCA, and UL , this model supports reliable deployment in enterprise servers, data centers, cloud systems, and high-performance computing platforms.

MODEL SELECTION

Compare Greatwall power options.

Review nearby Greatwall models and select the power level, output architecture, and form factor that best match the target system.

Model Power Input Voltage Efficiency Form Factor Best-Fit Application
CRPS1300N2 1300W 90VAC–264VAC or 180VDC–320VDC Platinum CRPS Balanced power for mainstream servers, storage systems, and cloud nodes
CRPS1600N3 1600W 90VAC–264VAC or 180VDC–320VDC Platinum CRPS Higher-load enterprise servers and infrastructure platforms with stronger expansion demand
CRPS2000N3 2000W 90VAC–264VAC or 180VDC–320VDC Platinum CRPS High-density compute platforms, advanced server nodes, and demanding 12V infrastructure systems

DEPLOYMENT SCENARIOS

Where CRPS2000N3 fits best.

The CRPS2000N3 is designed for server systems that require higher output capacity while still using a compact CRPS mechanical structure. It is suitable for data center servers, cloud computing nodes, storage platforms, high-performance computing systems, and enterprise infrastructure where strong 12V delivery, efficiency, and stable thermal behavior are important.

Scenario System Requirement Why CRPS2000N3 Fits
Data Center Servers High-capacity power for mission-critical rack servers 2000W output supports demanding compute and system-level loads
Cloud Computing Nodes Stable power delivery for scalable distributed infrastructure Platinum efficiency helps reduce power loss across large server deployments
Storage Platforms Reliable support for controllers, backplanes, drives, and cooling modules Multiple 12V output options provide flexibility for storage-focused systems
AI / HPC Systems Strong power headroom for advanced compute workloads 2000W capacity supports higher-density CPU, accelerator, and expansion configurations
Enterprise Infrastructure Continuous 24/7 operation for business-critical systems Wide input range and compact CRPS structure simplify deployment in server rooms
Advanced Network Platforms Stable power for high-throughput network and processing equipment High 12V current capacity supports heavier system loads and expansion hardware

POWER DESIGN

Reliability notes for continuous operation.

The CRPS2000N3 is built for high-density server platforms that need stronger 12V power delivery than 1300W or 1600W CRPS models. Its 2000W output capacity, Platinum efficiency, compact CRPS structure, and multiple main output configurations make it suitable for demanding infrastructure systems with higher processing, storage, and expansion requirements.

  • 2000W output capacity supports high-density server systems, cloud platforms, storage equipment, and advanced compute infrastructure.
  • Multiple 12V main output configurations provide flexibility for different platform power architectures and load requirements.
  • +12VSB / 3A standby output supports system standby logic, management functions, and auxiliary control circuits.
  • Platinum efficiency helps reduce power conversion loss and supports better thermal behavior in 24/7 operation.
  • Wide AC/DC input support allows the PSU to operate across different rack, cabinet, and data center power environments.
  • FR airflow direction supports standard front-to-rear cooling designs commonly used in server chassis.
  • Compact CRPS size helps deliver higher power density without requiring a larger PSU footprint.
  • Protection and certification coverage help support safer and more reliable use in enterprise and data center deployments.

INSTALLATION

Installation and operating guidance.

Confirm electrical compatibility, thermal clearance, mechanical fit, and system load before integration.

Installation / Operation Item Guidance
Load Planning Keep long-term load within a reasonable operating range to support stable output, efficiency, and service life
Chassis Fitment Confirm the system supports the 185 × 73.5 × 40 mm CRPS form factor before installation
Input Verification Use the power supply within the supported 90–264VAC or 180–320VDC input range
Output Matching Confirm the target platform supports the required 12V output configuration and standby power demand
Airflow Direction Make sure the FR airflow direction matches the chassis cooling path before deployment
Thermal Clearance Keep intake and exhaust areas open to avoid heat accumulation around the PSU bay
Module Installation Ensure the PSU is fully seated and properly connected before powering on the server
Routine Maintenance Check dust buildup, fan operation, connector condition, and overall thermal performance during regular service

FAQ

Frequently asked questions about CRPS2000N3.

Key answers for specification matching, installation planning, and system integration.

What type of power supply is the CRPS2000N3?

The CRPS2000N3 is a 2000W CRPS server power supply designed for high-density servers, cloud computing nodes, storage systems, and advanced infrastructure platforms.

What is the size of this model?

It uses a compact CRPS structure with dimensions of 185 × 73.5 × 40 mm.

What input voltage range does it support?

The CRPS2000N3 supports 90VAC–264VAC AC input and 180VDC–320VDC DC input.

What output does the CRPS2000N3 provide?

It provides +12V / 65.6A, +12V / 148A, and +12V / 164A main output configurations, together with +12VSB / 3A standby output.

Is this model suitable for high-density data center servers?

Yes. Its 2000W output capacity and compact CRPS form factor make it suitable for high-density server systems and demanding infrastructure platforms.

What airflow direction does this model support?

The CRPS2000N3 supports FR airflow, which is suitable for standard front-to-rear server chassis cooling designs.

What efficiency level does this power supply offer?

The CRPS2000N3 is rated at Platinum efficiency, helping improve energy utilization and reduce power conversion loss.

What certifications are listed for this model?

The listed certifications include CE, CQC, IRAM, TUV, UKCA, and UL.